Skip to main content Skip to search Skip to main navigation

Highlights

Im_930073201_eMobility_Ladesaeule_01_45221_45219 Icon_eMobility-perfect

Suitable for eMobility

Anw_SB25562_Rotational_field_indicator_100_700V_AC_CAT_IV_Control_Cabinet_05 Icon_700V_AC

Overvoltage protection, 600 V

Anw_SB25562_Rotational_field_indicator_100_700V_AC_CAT_IV_e-mobility_02 Icon_CAT_IV

Cat IV, 1,000 V

Anw_SB25562_Rotational_field_indicator_100_700V_AC_CAT_IV_High_Current_02 Icon_Drehfeld_L1_L2_L3

Rotating field determination and phase display

Anw_SB25562_Rotational_field_indicator_100_700V_AC_CAT_IV_Control_Cabinet_04

LED display

Product Description
Product description
Determining the direction of rotation in a three-phase power supply to check electrical connections? Not a problem with the Wiha rotational field indicator with integrated phase display. The rotation direction as well as the live phases are reliably indentified with the help of an LED display. In combination with the included test tips, the rotation indicator from Wiha offers great testing flexibility. The rotational field indicator works with the mains voltage itself, so no batteries are required. According to the measurement category CAT III up to 1,000 V and CAT IV up to 600 V the rotation indicator offers maximum safety for working directly on the source of low voltage installations.
Product dimensions
192 x 119 x 39 mm (LxWxD)
Standards
IEC/EN 61010-1, IEC/EN 61577-7, IEC/EN 611010-031, IP40
Application
Determination of the rotation direction and monitoring the phases.
Measuring category
CAT IV 600 V
Order number 45221
EAN 4010995452216
Phase display LED L1, L2, L3
Rotation field indication LED L, R
Warning LED Warnung
Voltage range phase against phase (V) 100V - 700V
Max. input voltage per phase (Lx) against neutral (N) 400 V
Current input 3.5 mA
Measuring category CAT IV 600 V
Contamination level 2
Height above sea level 2000 m
Operating temperature min - max (°C) 0 - 40°C
Protection class  IP IP40
LED and signal sound Yes
Measuring lines 3
Overvoltage protection (V) 600V
with battery / rechargeable battery No
Voltage V AC min – max 100 - 700
Voltage V DC min – max 100 - 700
Overall length (mm) 93 mm
Weight PU in grams 217
Phase display Phase display
Rotation field indication Rotation field indication
Warning Warning
Voltage range phase against phase (V) Voltage range phase against phase (V)
Max. input voltage per phase (Lx) against neutral (N) Max. input voltage per phase (Lx) against neutral (N)
Current input Current input
Measuring category Measuring category
Contamination level Contamination level
Operating temperature min - max (°C) Operating temperature min - max (°C)
Protection class  IP Protection class IP
LED and signal sound LED and signal sound
Measuring lines Measuring lines
Overvoltage protection (V) Overvoltage protection (V)
with battery / rechargeable battery with battery / rechargeable battery
Voltage V AC min – max Voltage V AC min – max
Voltage V DC min – max Voltage V DC min – max
Overall length (mm) Overall length (mm)
Weight PU in grams Weight PU in grams
Series 25560
Size specifications are always given in mm