Skip to main content Skip to search Skip to main navigation

Highlights

Anw_SB25513_Singlepole_noncontact_volt_detector_12_1000V_Cable_Channel_01 Icon_12-1000V_AC

Voltage 12 - 1,000 V AC

Anw_SB25513_Singlepole_noncontact_volt_detector_12_1000V_AC_emobility_09 Icon_CAT_IV

Cat IV, 1,000 V

Anw_SB25513_Singlepole_noncontact_volt_detector_12_1000V_AC_emobility_02

One-handed test

Anw_SB25513_Singlepole_noncontact_volt_detector_12_1000V_Electrical_Cabinet_01 Icon_Signal_Spannungspruefer_optisch

5-level optical signal

Anw_SB25513_Singlepole_noncontact_volt_detector_12_1000V_Cable_Channel_01 Icon_Taschenlampen-Funktion

Integrated flashlight function

Product Description
Product description
Before starting electrical installation work, electricians need to guarantee that their work environment is free of any live voltage. A voltage tester is required to test alternating electric fields or probable sources of error. The contactless Wiha voltage tester will give an initial indication of whether an area is live or not thanks to an optical and audible signal. Once the tester is switched on, the permanently green LED indicates that the tester is ready for use. During the voltage test, the LEDs will light up blue (weak), orange, or red (strong), depending on the strength of the alternating electric field. Two AAA batteries are required to operate the device. These are included in the delivery. The device switches off automatically to save energy if it is not used for four minutes. An integrated flashlight allows the user to illuminate the measurement point in dark environments and can be switched off and on manually for use solely as a flashlight. With its push-on clip, the voltage tester snugly fits into any shirt or trouser pocket thanks to its handy size. The voltage tester is suitable for all socket variants worldwide thanks to its measurement tip suited to international usage. Designed for CAT IV 1,000 V AC, the single-pole voltage tester complies with EN 61010-1/IEC 61326. The voltage tester should be tested on a known voltage source before and after every use to ensure it functions correctly.
Product dimensions
240 x 29 x 49 mm (LxWxD)
Standards
IEC/EN 61010-1, IEC/EN 61326, IP67
Application
Used to detect and locate live electrical cabling and wires, breaks and cable interruptions, blown fuses, defective light bulbs on light chains and single wires.
Measuring category
CAT IV 1.000 V
Order number 43797
EAN 4010995437978
Voltage V AC min – max 12 - 1000
Overall length (mm) 150 mm
Battery type (IEC designation) 2x AAA batteries
Handle diameter (mm) 28.5 mm
Remote voltage test Yes
ATEX approval No
Integrated flashlight Yes
Measuring category CAT IV 1.000 V
Protection class  IP IP67
Operating temperature min - max (°C) -20 - 40°C
Acoustic signal Yes
Weight PU in grams 100
Brutto / Netto £37.33 / £31.37
Voltage V AC min – max Voltage V AC min – max
Overall length (mm) Overall length (mm)
Battery type (IEC designation) Battery type (IEC designation)
Handle diameter (mm) Handle diameter (mm)
ATEX approval ATEX approval
Integrated flashlight Integrated flashlight
Measuring category Measuring category
Protection class  IP Protection class IP
Operating temperature min - max (°C) Operating temperature min - max (°C)
Acoustic signal Acoustic signal
Weight PU in grams Weight PU in grams
Series 25513
Size specifications are always given in mm